Tecknit Europe: Offering the very best in EMI Shielding
Shielding Components
Contact Dr.Shield® our EMI and RFI Shielding consultant Q.What is the best gasket to optimise the combination of shielding effectiveness and galvanic compatibility in a brass case exposed to salt spray?
Q. A properly tinned base material such as SN/CU/FE, phosphor, bronze or beryllium copper and a tinned or nickel plate on the brass case. (The tin plating must be continuous without pinholes, which can be called out to the wire manufacturer eg, reflow or electroles plating)would achieve optimum shielding effectiveness and galvanic compatibility.

Q. What are the elements that the rubber portion of duogaskets eliminate?
A. Moisture and dust.

Q. What procedure is recommended for mounting and positioning Interface Gaskets?
A. The application of small, thin dots of conductive adhesive on 3" spacings is the suggested procedure

Q. Which RFI Gasket can be used under water?
A. Both Elastomet and Duogasket can be used under water